Página 1 - VAX 4000 Model 200

VAX 4000 Model 200Troubleshooting and DiagnosticsOrder Number EK–437AB–TS–002Digital Equipment CorporationMaynard, Massachusetts

Página 2

Problem Possible Cause Corrective ActionCountdown does not con-tinue from 2 through 0;Break Enable/Disableswitch set to disable(down).System cannot lo

Página 3 - Contents

Problem Possible Cause Corrective ActionSystem will boot fromfixed disk if it is on line.Place fixed disk off line.Tape not bootable. Use tape containin

Página 4

Chapter 2Troubleshooting During NormalOperationProblems that occur during normal operation of your system may resultfrom a problem in the system, faul

Página 5

Problem Possible Cause Corrective ActionPower cable incorrectlyinstalled.Set Power switch to 0. Check thatcable is seated in socket. Set Powerswitch t

Página 6 - Conventions

2.2 RF-Series Integrated Storage Element (ISE)ProblemsProblem Possible Cause Corrective ActionWrite error message dis-plays; Write-Protect but-ton glo

Página 7 - Chapter 1

Problem Possible Cause Corrective ActionFour lights blinking. Failed self-test ordetected hard error.Push Unload button. If lights continueblinking, c

Página 8

Problem Possible Cause Corrective ActionPasses self-test; doesnot work.Problem in controlleror connection betweendrive and controller.Call your Digita

Página 9 - ?54 RETRY displays

2.6 TLZ04 Tape Drive ProblemsProblem Possible Cause Corrective ActionUnable to copy to tape;tape indicator yellow.Cassette write-protected. Set casset

Página 10 - Storage Element (ISE)

Chapter 3Running the MicroVAX DiagnosticMonitor (MDM)The MicroVAX Diagnostic Monitor (MDM) is an optional software packagecontaining diagnostic tests

Página 11

• MDM checks terminal interfaces (but not terminals) by means offeedback connectors.If your devices pass the tests but you still experience problems,

Página 12 - Operation

First Printing, December 1990Revised, June 1991The information in this document is subject to change without notice and should not beconstrued as a co

Página 13 - >>> dis

3.2.2 Preparing to Run MDM on an RF-Series IntegratedStorage Element (ISE) or Hard DiskYou can install MDM on an RF-series ISE or hard-disk drive by u

Página 14 - 2.3 TF85 Tape Drive Problems

2. Set the Break Enable/Disable switch on the host to be tested to enable(up).3. Insert a blank tape cartridge into the tape drive and lock it in plac

Página 15 - 2.4 TK50 Tape Drive Problems

3. Insert the tape cartridge containing MDM into the tape drive and lockit in place.4. Restart the host to be tested.5. After the self-test countdown

Página 16 - 2.5 TK70 Tape Drive Problems

• You can boot MDM manually from a TF85, TK50 or TK70 tape drive(Section 3.3.1.1).• You can use the autoboot feature to boot MDM only from a TK50 orTK

Página 17 - 2.6 TLZ04 Tape Drive Problems

3.3.1.2 Booting MDM AutomaticallyUse this procedure to boot MDM from a TK50 or TK70 tape drive. Do notuse this procedure for a TF85 tape drive.1. If s

Página 18 - Monitor (MDM)

5. Turn on your system (and the disc drive).6. Insert the disc caddy into the disc drive:a. Remove the disc from its package.b. Insert the disc into t

Página 19 - 3.2 Preparing to Run MDM

3.5 Main Menu OptionsThe Main Menu provides six options as shown in Figure 3–1.Figure 3–1: Main MenuMAIN MENU Release nnn Version xx.xx1 - Test the Sy

Página 20

in each name shows the difference. For example, DH–CX0A indicates oneoption, DH–CX0B a second, and so forth.If a device fails the test, you receive a

Página 21 - Bootfile:

3.5.2 Display System Configuration and Devices OptionThe Display System Configuration and Devices option identifies devicesrecognized by MDM.After you se

Página 22 - 3.3 Starting MDM

• KDA50 — Unit number, drive type, controller revision number• PDIA — DSSI adapter, embedded in KA660 CPU• DESQA — Ethernet station address• SGCA — On

Página 23

ContentsPreface viiChapter 1 Troubleshooting During Power-Up1.1 Autobooting the System Software . . . . . . . . . . . . . . . . . . . . . 1–11.2 Troub

Página 24

3.5.3 Display the System Utilities Menu OptionThe Display the System Utilities Menu option displays the System UtilitiesMenu. If system utilities in a

Página 25 - 3.4 MDM Introductory Display

3.5.3.2 Update Drive Unit Number for RRD-Series FunctionThe Update Drive Unit Number function lets you update the unit numberfor an RRD-series disc dr

Página 26 - 3.5 Main Menu Options

Figure 3–5: Select Single Device Test MenuMAIN MENU Release nnn Version xx.xxSELECT SINGLE DEVICE TESTSelect the device number to be tested. The funct

Página 27

Figure 3–6: Example of a Successful TestBEGIN FUNCTIONAL TESTDevice ResultCPUA ... PASSEDBEGIN EXERCISER TESTResults are reported at t

Página 28

3.6 Exiting MDMExit MDM in one of the following ways.• PressBreak.• Press and then release the Halt button.• Press the Restart (BA215: Restart/Run) bu

Página 29

Appendix ASystem Controls and IndicatorsThe illustrations in this appendix show the controls and indicators on yoursystem:Figure A–1: BA430 System Con

Página 30

Figure A–1: BA430 System Control Panel and Power SupplyDC OK IndicatorOver TemperatureWarning IndicatorHalt ButtonRestart ButtonSystem ControlPanelPow

Página 31

Figure A–2: BA430 CPU Cover PanelLED DisplayPower-UpModifiedModular JackEthernetConnector SwitchThinWire EthernetConnectorEnable/DisableStandardEthern

Página 32

Figure A–3: BA215 CPU Cover PanelA1StandardEthernetConnectorLEDDisplayPower-UpMode SwitchModifiedModularJackThinWireEthernetConnectorBreakEnable/Disab

Página 33

Figure A–4: BA215 Power SupplyResetButtonDC OKLightCircuitBreakerA1PowerSupplyMLO-000680System Controls and Indicators A–9

Página 34 - 3.6 Exiting MDM

3.3 Starting MDM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–53.3.1 Tape Drive Instructions . . . . . . . . . . . . . .

Página 35 - Appendix A

Figure A–5: BA215 Operator Control PanelMLO-005512DRIVEUnit NumberFaultWrite- ProtectReady2 1 0SYSTEMRestart/RunHaltISE Controls and IndicatorsSystem

Página 36 - Power Supply

Figure A–6: TK50 and TK70 Tape DrivesOrange LightYellow LightGreen LightUnload ButtonHandleTK70 TAPE DRIVEGreenIndicatorLightLoad/UnloadButton,Red Lig

Página 37 - CPU Cover Panel

Figure A–7: TF85 and TLZ04 Tape DrivesTF85 TAPE DRIVETape IndicatorUnload ButtonTo LoadTo UnloadWriteProtectedTape in UseUseCleaningTapeOperateHandleU

Página 38 - MLO-000679

IndexAAutobooting system, 1–1BBootingpower-up problems, 1–3RF-series integrated storageelement problems, 1–4system, 1–1tape problems, 1–4Booting Micro

Página 39 - MLO-000680

Hard Disk Kit, MicroVAX DiagnosticMonitor, 3–3IIndicators, system, A–1Integrated storage elementSee RF-series integrated storageelementIntroductory di

Página 40 - ISE Controls and Indicators

MicroVAX Diagnostic Monitor(Cont.)Select Single Device Tests option,Main Menu, 3–14starting, 3–5starting, booting TK50/TK70tape, 3–5starting, booting

Página 41 - TK50 TAPE DRIVE

System (Cont.)controls and indicators, A–1diskless or tapeless, preparing torun MicroVAX DiagnosticMonitor, 3–2dual-host, preparing to runMicroVAX Dia

Página 42 - TLZ04 TAPE DRIVE

A–6 TK50 and TK70 Tape Drives . . . . . . . . . . . . . . . . . . . . . . . . . A–13A–7 TF85 and TLZ04 Tape Drives . . . . . . . . . . . . . . . . . .

Página 43

PrefaceTroubleshooting is the process of isolating and diagnosing problems. Whenyour system does not operate as described in your Operation manual, us

Página 44

Chapter 1Troubleshooting During Power-UpAfter you turn on your system, the processor performs a series of self-testsand startup routines. After succes

Página 45

Problem Possible Cause Corrective ActionPower switch tripped to0. (BA215: Circuitbreaker tripped.)Wait 1 minute, then set Power switchto 1. (BA215: Se

Página 46

Problem Possible Cause Corrective ActionSystem has power; LEDcounting down; DC OKindicator lit; nothing dis-plays on console termi-nal.Problem with CP